Digital Differential Pressure Gauge Colour Display
Minimum Order Quantity: 1 Piece
Product Brochure
Pressure Type | Differential Pressure |
Model Name/Number | AI-PG101 |
Make | Ace Instruments |
Display | TFT Display |
Country of Origin | Made in India |
The differential pressure gauge(tft display) has an in built buzzer alarm for alert on low alarm & high alarm limit violation with buzzer acknowledgement key facility. It has a depth of 30 mm. & diameter of 4.5 inches , thus making it a perfect fit into analog gauge cutouts for retrofitting. Fits easily into the same cutout as a Magnehelic gauge or the cutout of Sensocon digital gauge.
Pressure measuring ranges are available from -50 to + 50 Pascals, 0 to 100 Pascals, 0 to 500 Pascals, 0 to 1000 Pascals, 0.0 to 10.0mm.W.C., -10.0 to +10.0 mm.W.C. & various other customized ranges & engineering units like Inch. w.c., kpa, inches.wc., etc.
Application: Laminar air flow cabinets, clean rooms, bio safety cabinets, air handling units, filters, etc.
Digital differential pressure gauges with TFT display are exported to more than 20 countries including UAE, Kingdom of Saudi Arabia, Dubai, Bangladesh, Egypt, USA, South Africa, Brazil, Argentina , U.K., France, Poland, Bulgaria, Indonesia, Philippines, South Africa, Kenya, Uganda, Saudi Arabia, Vietnam, Thailand, etc.
Additional Information:
- Item Code: 90261010
- Production Capacity: 100
- Delivery Time: ready stock
Air Change Per Hour Rate & Differential Pressure Monitor for Sterile Production Area
Product Brochure
Dial Size | 6 inch / 150 mm |
Display Type | Digital |
Use | Pharmaceutical Industries |
Mounting | Wall mounting/Modular mounting |
Material of Casing | Plastic |
Model Name/Number | AI-CRS4-IA-TFT |
Country of Origin | Made in India |
The Air Change Per Hour Monitor by ACE Instruments ensures compliance with ASHRAE Standard 170 for healthcare facilities, US FDA aseptic guidelines for sterile production areas, EU GMP requirements, and ISO 14644 standards.
The Hospital Air Change per Hour Monitor (Model: AI-CRS4-IA-TFT) features a 5” full-color TFT touch screen that supports sensors for temperature, humidity, differential pressure, and ACH. It has a high-resolution display and helps maintain compliance with Ministry of Health guidelines in Saudi Arabia for hospital clean room monitoring, as well as FDA and cGMP standards in pharmaceutical aseptic and cleanroom environments.
The monitor offers an easy-to-read 4-line display with engineering units for each input. The AI-CRS-IA-TFT model provides real-time display options.
The device includes an integrated buzzer alarm to alert for any process limit violations across the four parameters: temperature, humidity, differential pressure, and ACH.
Specially designed for hospital isolation rooms and operating theatre rooms, the Hospital Air Change per Hour Monitor (Model: AI-CRS4-IA-TFT) includes the following features:
- Multi-row (4 rows) 5” full-color touch TFT with individual parameter engineering unit display
- Built-in buzzer for alarm alerts on each channel
- Sensors available for all four parameters
- RS 485 Modbus communication, with optional Ethernet TCP/IP communication
This product is exported regularly to various countries including the USA, Poland, Italy, Dubai, UAE, Oman, Qatar, Saudi Arabia, Nigeria, Kenya, Egypt, Australia, UK, France, Italy, Bangladesh, Thailand, Malaysia, Qatar, Singapore, Romania, Belgium, Russia, Brazil, Germany, and Vietnam.
It ensures environmental compliance in GMP cleanroom environments and meets Ministry of Health standards for isolation room and operating theatre monitoring in Saudi Arabia, Qatar, and Oman. It is also compatible with USFDA-21 CFR Part 11 and GAMP-4 for data logging and EMS SCADA software.
Frequently Asked Questions about Air Change Per Hour Rate & Differential Pressure Monitor :
1.Is the Air Change Per Hour ACH Monitor(CRS4-IA-TFT) CE Certified?
Yes, the Air Change Per Hour ACH Monitor is CE certified & ensures that Temperature, Humidity, Differential Pressure and Air Change per Hour monitoring is made possible according to global quality standards.
2.What parameters does the Air Change Per Hour ACH Monitor(CRS4-IA-TFT) measure?
The Ace Instruments Air Change Per Hour ACH Monitor is engineered to reliably measure Temperature, Humidity, Differential Pressure and Air Change per Hour.
3.What communication protocols are available?
Air Change Per Hour ACH Monitor(CRS4-IA-TFT) supports versatile connectivity options. They include:
Modbus: Seamless integration with industrial controllers and automation systems.
Ethernet: Provides network connectivity via Ethernet TCP/IP and allows both power and data transmission over a single cable.
4.What support and warranty options are available?
Air Change Per Hour ACH Monitor(CRS4-IA-TFT) is backed by a 12 months manufacturer warranty and dedicated technical support. Our support team is available to assist with installation, troubleshooting, and customization.